CPU
NOCPU |
Specifies whether system CPU activity
is to be monitored |
CHAN
NOCHAN |
Specifies whether system channel
activity is to be monitored. |
DEVICE(dev list)
NODEVICE |
Specifies whether sytem device activity
is to be monitored. If device activity is to be monitored
(DEVICE specified), a device list indicates the classes of devices
that will be monitored. When the DEVICE parameter is
specified, a device list must be included. |
|
CHRDR
NOCHRDR |
Character reader devices |
|
COMM
NOCOMM |
Communication equipment |
|
DASD
NODASD |
Direct access storage devices |
|
GRAPH
NOGRAPH |
Graphics devices |
|
TAPE
NOTAPE |
Magnetic tape devices |
|
UNITR
NOUNITR |
Unit record devices |
PAGING
NOPAGING |
Specifies whether system
paging activity is to be monitored. |
WKLD(PERIOD)
WKLD(GROUP)
WKLD(SYSTEM)
NOWKLD |
Specified whether system
workload activity is to be monitored. If workload activity
is to be monitored (WKLD specified), the level of detail of the
report to be produced must be specified. PERIOD requests the
most detailed level by performance group period; GROUP requests
reporting by performance group; SYSTEM requests a system summary
report. |
CYCLE(value) |
Specifies the frequency at
which sampling observations are to be made of channel and device
data. The range is from 50 to 999 milliseconds. The
default is 250 milliseconds. |
INTERVAL
(Value)
(Value M) |
Specifies the interval at
which all data will be gathered for report formatting and/or SMF
record writing. The range is from 1 to 60 minutes. The
default is 15M. |
MEMBER(nn) |
The value specified by this
parameter is appended to IRBMF1 to form the name of the
partitioned data set member that contains the MF/1 options.
This parameter may be specified in the PARM field of the START
command or EXEC statement, but should not be specified within a
partitioned data set member. The default is 00, indicating
member IRBMF100 in SYS1.PARMLIB. |
OPTIONS
OPTN
NOOPTIONS
NOOPTN |
Specifies whether or not a
list of the options to be used will be printed at the operator's
console at MF/1 initialization. If the list is printed
(OPTIONS or OPTN is specified), the operator will be able to
respond with any desired changes to the option list. |
RECORD
NORECORD |
Specifies whether monitored
data is to be written to the SMF data set. If SMF records
are to be written, SMF data recording must have been specified at
IPL as MAN=ALL. |
REPORT(REALTIME)
REPORT(DEFER)
NOREPORT |
Specifies whether or not
printed reports of the monitored data are to be produced. If
the reports are to be produced (REPORT is specified), the REALTIME/DEFER
options specify whether the reports are to be printed when
formatted at the conclusion of a data gathering interval (REALTIME
is specified), or printed after MF/1 processing ends(DEFER is
specified). |
STOP(value)
STOP(value H)
STOP(value M)
NOSTOP |
Specifies the desired time
duration for MF/1 activity in minutes or hours. The range is
from one minute to one week (168 hours or 10,080 minutes).
The units default is M (minutes). The default value is
15M. The operator STOP command can terminate execution at
any time, regardless of the value for this parameter. |
SYSOUT(class) |
Specifies the SYSOUT class
to which formatted reports are directed. Class A is the
default. |